title: "Cooling coil sizing: why temperature and humidity matters"
description: Choosing a cooling coil for an air handling unit (AHU) is more than a technical decision - it impacts system efficiency, investment costs and energy use.
image: https://blog.swegon.com/hubfs/AdobeStock_847930039.jpeg
---

[![](https://www.swegon.com/Static/img/logo.svg?v=3)](https://www.swegon.com/)

Menu

- [Solutions & services](https://www.swegon.com/solutions-and-services/)
- [Products](https://www.swegon.com/products/)
- [References & Insights](https://www.swegon.com/references-and-insights/)
- [Support & software](https://www.swegon.com/support/)
- [Sustainability](https://www.swegon.com/sustainability/)
- [Why Swegon?](https://www.swegon.com/why-swegon/)

- [Product Search](https://www.swegon.com/product-search-result/)
- [Document Search](https://www.swegon.com/support/find-documents/)
- [Career](https://www.swegon.com/career/)
- Global
- [Contact](https://www.swegon.com/contact/)

## Choose a market

[Or visit our global site](https://www.swegon.com)

- [Belgium - French](https://www.swegon.com/fr-be/)
- [Belgium - Dutch](https://www.swegon.com/nl-be/)
- [Denmark](https://www.swegon.com/da/)
- [Finland](https://www.swegon.com/fi/)
- [France](https://www.swegon.com/fr/)
- [Italy](https://www.swegon.com/it/)
- [Germany](https://www.swegon.com/de/)
- [Norway](https://www.swegon.com/no/)
- [Poland](https://www.swegon.com/pl/)
- [Spain](https://www.swegon.com/es/)
- [Sweden](https://www.swegon.com/sv/)
- [Switzerland - German](https://www.swegon.com/de-ch/)
- [Switzerland - French](https://www.swegon.com/fr-ch/)
- [Switzerland - Italian](https://www.swegon.com/it-ch/)
- [United Kingdom](https://www.swegon.com/uk/)
- [United States](https://www.swegonnorthamerica.com)
- [Canada](http://swegonnorthamerica.com/)

Explore

## Filter articles

### By topics

- [Indoor Climate Knowledge (55)](https://blog.swegon.com/en/tag/indoor-climate-knowledge)
- [Cooling & Heating (27)](https://blog.swegon.com/en/tag/cooling-heating)
- [Energy Efficiency (23)](https://blog.swegon.com/en/tag/energy-efficiency)
- [Sustainability (23)](https://blog.swegon.com/en/tag/sustainability)
- [Air Handling Units (22)](https://blog.swegon.com/en/tag/air-handling-units)
- [Room Units (21)](https://blog.swegon.com/en/tag/room-units)
- [Heat Pumps (12)](https://blog.swegon.com/en/tag/heat-pumps)
- [Acoustics (9)](https://blog.swegon.com/en/tag/acoustics)
- [Optimisation Systems (9)](https://blog.swegon.com/en/tag/optimisation-systems)
- [Humidity (7)](https://blog.swegon.com/en/tag/humidity)
- [Services & Connectivity (7)](https://blog.swegon.com/en/tag/services-connectivity)
- [Renovation (6)](https://blog.swegon.com/en/tag/renovation)
- [Schools (4)](https://blog.swegon.com/en/tag/schools)
- [Software (4)](https://blog.swegon.com/en/tag/software)
- [BIM (3)](https://blog.swegon.com/en/tag/bim)
- [Gender Equality (3)](https://blog.swegon.com/en/tag/gender-equality)
- [Air Quality (2)](https://blog.swegon.com/en/tag/air-quality)

> Fler

### By authors

- [![Alberto Ferrandi](https://blog.swegon.com/hs-fs/hubfs/Bild%20alberto.png?width=75&name=Bild%20alberto.png) Alberto Ferrandi 6](https://blog.swegon.com/en/author/alberto-ferrandi)
- [![Alberto Frison](https://blog.swegon.com/hs-fs/hubfs/alberto.jpg?width=75&name=alberto.jpg) Alberto Frison 2](https://blog.swegon.com/en/author/alberto-frison)
- [![Alessandro Lora](https://blog.swegon.com/hs-fs/hubfs/lora.webp?width=75&name=lora.webp) Alessandro Lora 3](https://blog.swegon.com/en/author/alessandro-lora)
- [![Alessandro Pinato](https://blog.swegon.com/hs-fs/hubfs/alessandro.webp?width=75&name=alessandro.webp) Alessandro Pinato 9](https://blog.swegon.com/en/author/alessandro-pinato)
- [![Anders Jakobsson](https://blog.swegon.com/hs-fs/hubfs/Anders%20Jacobsson_4.jpg?width=75&name=Anders%20Jacobsson_4.jpg) Anders Jakobsson 3](https://blog.swegon.com/en/author/anders-jakobsson)
- [![Andreas Söderholm](https://blog.swegon.com/hs-fs/hubfs/andreassoderholm.webp?width=75&name=andreassoderholm.webp) Andreas Söderholm 1](https://blog.swegon.com/en/author/andreas-söderholm)
- [![Andreas Örje Wellstam](https://blog.swegon.com/hs-fs/hubfs/andreas-orje-wellstam.webp?width=75&name=andreas-orje-wellstam.webp) Andreas Örje Wellstam 5](https://blog.swegon.com/en/author/andreas-örje-wellstam)
- [![Anna Sundell](https://blog.swegon.com/hs-fs/hubfs/Anna.jpg?width=75&name=Anna.jpg) Anna Sundell 1](https://blog.swegon.com/en/author/anna-sundell)
- [![Bastien Stocq](https://blog.swegon.com/hs-fs/hubfs/Bastien.png?width=75&name=Bastien.png) Bastien Stocq 1](https://blog.swegon.com/en/author/bastien-stocq)
- [![Björn Erlingsson](https://blog.swegon.com/hs-fs/hubfs/bjornerling.png?width=75&name=bjornerling.png) Björn Erlingsson 1](https://blog.swegon.com/en/author/björn-erlingsson)
- [![Börje Lehrman](https://blog.swegon.com/hs-fs/hubfs/Blog%20Authors/SE-SV%20-%20PRO%20-%20BACV/B%C3%B6rje_Lehrman.jpg?width=75&name=B%C3%B6rje_Lehrman.jpg) Börje Lehrman 3](https://blog.swegon.com/en/author/börje-lehrman)
- [![Caroline Jacobsson](https://blog.swegon.com/hs-fs/hubfs/Blog%20Authors/Caroline%20Jacobsson.jpg?width=75&name=Caroline%20Jacobsson.jpg) Caroline Jacobsson 10](https://blog.swegon.com/en/author/caroline-jacobsson)
- [![Elvis Kokot](https://blog.swegon.com/hs-fs/hubfs/elviskokot.png?width=75&name=elviskokot.png) Elvis Kokot 1](https://blog.swegon.com/en/author/elvis-kokot)
- [![Fabio Polo](https://blog.swegon.com/hs-fs/hubfs/Fabio%20Polo-1.jpg?width=75&name=Fabio%20Polo-1.jpg) Fabio Polo 9](https://blog.swegon.com/en/author/fabio-polo)
- [![Francesco Artusi](https://blog.swegon.com/hs-fs/hubfs/Francesco%20Artusi%20CUT.jpg?width=75&name=Francesco%20Artusi%20CUT.jpg) Francesco Artusi 1](https://blog.swegon.com/en/author/francesco-artusi)
- [![François Jouvray](https://blog.swegon.com/hs-fs/hubfs/francois%20Jouvray2.jpg?width=75&name=francois%20Jouvray2.jpg) François Jouvray 1](https://blog.swegon.com/en/author/françois-jouvray)
- [![Jan Scheuring](https://blog.swegon.com/hs-fs/hubfs/Photo_Jan-1.jpeg?width=75&name=Photo_Jan-1.jpeg) Jan Scheuring 3](https://blog.swegon.com/en/author/jan-scheuring)
- [![John Wibrand](https://blog.swegon.com/hs-fs/hubfs/John%20Wibrand.jpg?width=75&name=John%20Wibrand.jpg) John Wibrand 2](https://blog.swegon.com/en/author/john-wibrand)
- [![Josh Emerson](https://blog.swegon.com/hs-fs/hubfs/Josh_Emerson_Headshot.jpg?width=75&name=Josh_Emerson_Headshot.jpg) Josh Emerson 1](https://blog.swegon.com/en/author/josh-emerson)
- [![Luca Filippetto](https://blog.swegon.com/hs-fs/hubfs/Luca%20Filippetto%20Hubspot.jpg?width=75&name=Luca%20Filippetto%20Hubspot.jpg) Luca Filippetto 4](https://blog.swegon.com/en/author/luca-filippetto)
- [![Luca Zordan](https://blog.swegon.com/hs-fs/hubfs/lucazordan.png?width=75&name=lucazordan.png) Luca Zordan 1](https://blog.swegon.com/en/author/luca-zordan)
- [![Magnus Andersson](https://blog.swegon.com/hs-fs/hubfs/magnus%20andersson_550x550%20(1).jpg?width=75&name=magnus%20andersson_550x550%20(1).jpg) Magnus Andersson 1](https://blog.swegon.com/en/author/magnus-andersson)
- [![Malin Höij](https://blog.swegon.com/hs-fs/hubfs/malinh.webp?width=75&name=malinh.webp) Malin Höij 5](https://blog.swegon.com/en/author/malin-höij)
- [![Markus Schomaker](https://blog.swegon.com/hs-fs/hubfs/Dr.-Ing.%20Markus%20Schomaker_Quadratisch.jpg?width=75&name=Dr.-Ing.%20Markus%20Schomaker_Quadratisch.jpg) Markus Schomaker 2](https://blog.swegon.com/en/author/markus)
- [![Martin Ottersten](https://blog.swegon.com/hs-fs/hubfs/Blog%20Authors/Martin_Ottersten.jpg?width=75&name=Martin_Ottersten.jpg) Martin Ottersten 4](https://blog.swegon.com/en/author/martin-ottersten)
- [![Mike Ward](https://blog.swegon.com/hs-fs/hubfs/Michael_Ward_photo.jpg?width=75&name=Michael_Ward_photo.jpg) Mike Ward 5](https://blog.swegon.com/en/author/michael-ward)
- [![Mikael Börjesson](https://blog.swegon.com/hs-fs/hubfs/Blog%20Authors/Mikael%20B%C3%B6rjesson.jpg?width=75&name=Mikael%20B%C3%B6rjesson.jpg) Mikael Börjesson 30](https://blog.swegon.com/en/author/mikael-börjesson)
- [![Mirko Sauvan](https://blog.swegon.com/hs-fs/hubfs/Swegon_Mirko%20Sauvan_web_3.jpg?width=75&name=Swegon_Mirko%20Sauvan_web_3.jpg) Mirko Sauvan 2](https://blog.swegon.com/en/author/mirko-sauvan-1)
- [![Niklas Jacobsson](https://blog.swegon.com/hs-fs/hubfs/authorniklas.png?width=75&name=authorniklas.png) Niklas Jacobsson 2](https://blog.swegon.com/en/author/niklas-jacobsson)
- [![Paola Moschini](https://blog.swegon.com/hs-fs/hubfs/forfattare.webp?width=75&name=forfattare.webp) Paola Moschini 1](https://blog.swegon.com/en/author/paola-moschini)
- [![Philip Wikström](https://blog.swegon.com/hs-fs/hubfs/Philip_Andersson_pressbild_small_webb.jpg?width=75&name=Philip_Andersson_pressbild_small_webb.jpg) Philip Wikström 3](https://blog.swegon.com/en/author/philip-wikstrom)
- [![Robert Siverby](https://blog.swegon.com/hs-fs/hubfs/MicrosoftTeams-image%20(3)-4.png?width=75&name=MicrosoftTeams-image%20(3)-4.png) Robert Siverby 1](https://blog.swegon.com/en/author/robert-siverby)
- [![Stefan Lay](https://blog.swegon.com/hs-fs/hubfs/1517033472060.jpg?width=75&name=1517033472060.jpg) Stefan Lay 1](https://blog.swegon.com/en/author/stefan-lay)
- [![Swegon](https://blog.swegon.com/hs-fs/hubfs/swegsw-1.png?width=75&name=swegsw-1.png) Swegon 3](https://blog.swegon.com/en/author/swegon)
- [![Timo Schreck](https://blog.swegon.com/hs-fs/hubfs/Timo%20Schreck.jpg?width=75&name=Timo%20Schreck.jpg) Timo Schreck 2](https://blog.swegon.com/en/author/timo-schreck)
- [![Tobias Nordström](https://blog.swegon.com/hs-fs/hubfs/TobiasNordstromPHOTO.jpg?width=75&name=TobiasNordstromPHOTO.jpg) Tobias Nordström 5](https://blog.swegon.com/en/author/tobias-nordström)
- [![Tomi Laakso](https://blog.swegon.com/hs-fs/hubfs/Blog%20Authors/TomiLaakso.jpg?width=75&name=TomiLaakso.jpg) Tomi Laakso 1](https://blog.swegon.com/en/author/tomi-laakso)
- [![Tony Olsson](https://blog.swegon.com/hs-fs/hubfs/Tony%20Olsson.webp?width=75&name=Tony%20Olsson.webp) Tony Olsson 6](https://blog.swegon.com/en/author/tony-olsson)
- [![Tony Pettersson](https://blog.swegon.com/hs-fs/hubfs/tonyp.jpg?width=75&name=tonyp.jpg) Tony Pettersson 1](https://blog.swegon.com/en/author/tony-pettersson)
- [![Welat Han](https://blog.swegon.com/hs-fs/hubfs/Welat%20Han.jpg?width=75&name=Welat%20Han.jpg) Welat Han 3](https://blog.swegon.com/en/author/welat-han)
- [![William Lawrance](https://blog.swegon.com/hs-fs/hubfs/William2.jpg?width=75&name=William2.jpg) William Lawrance 12](https://blog.swegon.com/en/author/william-lawrance)
- [![Åsa Norén-Lundh](https://blog.swegon.com/hs-fs/hubfs/A%CC%8Asa%20Nore%CC%81n-Lundh.webp?width=75&name=A%CC%8Asa%20Nore%CC%81n-Lundh.webp) Åsa Norén-Lundh 6](https://blog.swegon.com/en/author/åsa-norén-lundh)

Explore

- <https://twitter.com/share?url=https%3A%2F%2Fblog.swegon.com%2Fen%2Fcooling-coil-sizing-why-temperature-and-humidity-matters>
- <https://www.linkedin.com/shareArticle?mini=true&url=https%3A%2F%2Fblog.swegon.com%2Fen%2Fcooling-coil-sizing-why-temperature-and-humidity-matters>
- <https://www.facebook.com/sharer.php?u=https%3A%2F%2Fblog.swegon.com%2Fen%2Fcooling-coil-sizing-why-temperature-and-humidity-matters>

[The Swegon Blog](https://blog.swegon.com/en?hsLang=en)

 Subscribe

 Share

- <https://twitter.com/share?url=https%3A%2F%2Fblog.swegon.com%2Fen%2Fcooling-coil-sizing-why-temperature-and-humidity-matters>
- <https://www.linkedin.com/shareArticle?mini=true&url=https%3A%2F%2Fblog.swegon.com%2Fen%2Fcooling-coil-sizing-why-temperature-and-humidity-matters>
- <https://www.facebook.com/sharer.php?u=https%3A%2F%2Fblog.swegon.com%2Fen%2Fcooling-coil-sizing-why-temperature-and-humidity-matters>

Explore

Share

Subscribe

[« go back](https://blog.swegon.com/en)

# Cooling coil sizing: why temperature and humidity matters

[William Lawrance](https://blog.swegon.com/en/author/william-lawrance)

 2/19/25, 3:00 AM

**When selecting cooling coils for air handling units, it is essential to use relevant input data to ensure that the cooling power is appropriately sized. Oversized cooling coils lead to oversized chillers, which can significantly increase the investment cost. This blog post written by William Lawrance, Senior Product Manager Special Projects,explains this issue in detail with the help of a practical example and by using Mollier diagrams for temperature and humidity calculations.**

 

Energy is removed from the air when it is cooled and the amount of energy in the air depends on both temperature and humidity. So, when selecting a cooling coil it is important to ensure that the correct temperature and humidity of the air as it enters the cooling coil is used in the calculation. The relationship between temperature and humidity is called enthalpy, and the change in enthalpy represents the cooling energy.

The outdoor air temperature and humidity fluctuate depending on the weather conditions, but they do so independently of one another. A typical scenario is the morning, when there is a change in temperature and humidity – the temperature rises and humidity levels decrease.

The graphs below illustrate this relationship, showing temperature, humidity and enthalpy on the warmest day of the test period.

![](https://blog.swegon.com/hs-fs/hubfs/image-png-Feb-18-2025-12-30-15-5658-PM.png?width=732&height=519&name=image-png-Feb-18-2025-12-30-15-5658-PM.png)

During midday, it is apparent that the highest temperature roughly coincides with the lowest relative humidity. This is logical because warmer air can hold more moisture than colder air. As a result it is obvious that the maximum enthalpy occurs approximately at the maximum temperature. Knowing this, it is evident that temperature and humidity measures should be selected from the same point in time.

When designing an AHU with a cooling coil, the selected temperature and humidity levels are normally slightly lower than the maximum levels. There are different methodologies for making this selection but what is essential is that the temperature and humidity are coincidental.

The unfavourable consequence of selecting the maximum temperature and humidity independently is explained in the following example:

First of all, cooling coils in comfort applications are generally sized for a supply air temperature of 17 degrees Celsius (AHU Design statistical data).

![](https://blog.swegon.com/hs-fs/hubfs/image-png-Feb-18-2025-01-03-13-5777-PM.png?width=690&height=294&name=image-png-Feb-18-2025-01-03-13-5777-PM.png)

Calculations are made for Norrköping, Sweden, using the actual outdoor air conditions given in the table below. Valencia and Madrid, Spain, as well as London, UK, are used to demonstrate the concept.

![](https://blog.swegon.com/hs-fs/hubfs/image-png-Feb-18-2025-12-34-33-1914-PM.png?width=720&height=217&name=image-png-Feb-18-2025-12-34-33-1914-PM.png)

When the Norrköping, Sweden, case is plotted in the Mollier diagram, the results show that the calculated cooling power based on maximum humidity rather than the correct values of humidity, results in a cooling power that is more than three times higher.

![](https://blog.swegon.com/hs-fs/hubfs/image-png-Feb-18-2025-12-36-52-1919-PM.png?width=854&height=310&name=image-png-Feb-18-2025-12-36-52-1919-PM.png)

![](https://blog.swegon.com/hs-fs/hubfs/image-png-Feb-18-2025-12-37-15-5553-PM.png?width=814&height=189&name=image-png-Feb-18-2025-12-37-15-5553-PM.png)

The findings confirm that it is important to use the correct humidity data when selecting cooling coils.

**Energy recovery**

The above example is calculated without considerations made to cooling energy recovery. When taking that parameter into account, the cooling coil power can be substantially reduced when a sorption rotary exchanger is used to recover cooling energy.

To exemplify, using the Norrköping case again, assuming a supply air temperature of 17°C and an extract air temperature of 23°C with 55% relative humidity. The rotary heat exchanger has a temperature efficiency of 81.1% and a humidity efficiency of 80.9%.

![](https://blog.swegon.com/hs-fs/hubfs/image-png-Feb-18-2025-12-38-01-3397-PM.png?width=738&height=365&name=image-png-Feb-18-2025-12-38-01-3397-PM.png)

A sorption rotary heat exchanger removes moisture from the outdoor air and transfers it to the exhaust air. It also reduces the temperature by 2-3 degrees Celsius, which replaces about one-third of the needed cooling power. In moderate cooling scenarios like this, the sorption rotor provides the additional benefit of a significantly drier supply air. To reach the same moisture content in the supply air using only a cooling coil would require cooling the air to 13°C and that in turn would result in a cooling power demand some 70% higher than that of the setup with a sorption rotor. So, the sorption rotary exchanger reduces the cooling power and allow for a smaller chiller, hence a lower refrigerant charge. In addition, the chiller energy consumption is significantly reduced.

 

For more information on this topic, see our blog post about [sorption technology](https://blog.swegon.com/en/the-many-advantages-of-sorption-technology?hsLang=en), learn more about [dry cooling](https://blog.swegon.com/en/what-are-the-advantages-of-dry-cooling?hsLang=en) and get familiar with [AHU Design](https://www.swegon.com/support/software/ahu-design/) – our product selection software that makes the selection of cooling coils both easy and correct.

Topics:

- [Energy Efficiency](https://blog.swegon.com/en/tag/energy-efficiency)
- [Air Handling Units](https://blog.swegon.com/en/tag/air-handling-units)

- <https://twitter.com/share?url=https%3A%2F%2Fblog.swegon.com%2Fen%2Fcooling-coil-sizing-why-temperature-and-humidity-matters>
- <https://www.linkedin.com/shareArticle?mini=true&url=https%3A%2F%2Fblog.swegon.com%2Fen%2Fcooling-coil-sizing-why-temperature-and-humidity-matters>
- <https://www.facebook.com/sharer.php?u=https%3A%2F%2Fblog.swegon.com%2Fen%2Fcooling-coil-sizing-why-temperature-and-humidity-matters>

[![William Lawrance](https://blog.swegon.com/hs-fs/hubfs/William2.jpg?width=200&name=William2.jpg)](https://blog.swegon.com/en/author/william-lawrance)

[William Lawrance](https://blog.swegon.com/en/author/william-lawrance)

 With more than 40 years of experience in the industry, William Lawrance is a Senior Product Manager at Swegon. William is also the Convenor for the CEN workgroup, responsible for preparing the AHU standards EN 13053 and EN 1886, as well as the Chairman of Eurovent Certification Compliance Committee for AHU.

## Recommended reading

- [Energy Efficiency](https://blog.swegon.com/en/tag/energy-efficiency)
- [Indoor Climate Knowledge](https://blog.swegon.com/en/tag/indoor-climate-knowledge)
- [Room Units](https://blog.swegon.com/en/tag/room-units)

### [Tobias Nordström](https://blog.swegon.com/en/author/tobias-nordström)

## [Chilled beams re-invented: Maintaining performance in a world of variable airflow](https://blog.swegon.com/en/chilled-beams-re-invented-maintaining-performance-in-a-world-of-variable-airflow-clone?hsLang=en)

 For decades, one of the strongest selling points of chilled beams has …

- [Energy Efficiency](https://blog.swegon.com/en/tag/energy-efficiency)
- [Sustainability](https://blog.swegon.com/en/tag/sustainability)

### [Mikael Börjesson](https://blog.swegon.com/en/author/mikael-börjesson)

## [Beyond energy efficiency, the revised EPBD puts IEQ in focus](https://blog.swegon.com/en/beyond-energy-efficiency-the-revised-epbd-puts-ieq-in-focus?hsLang=en)

 The latest revision of the Energy Performance of Buildings Directive …

- [Energy Efficiency](https://blog.swegon.com/en/tag/energy-efficiency)
- [Room Units](https://blog.swegon.com/en/tag/room-units)

### [Jan Scheuring](https://blog.swegon.com/en/author/jan-scheuring)

## [Why meeting HVAC design challenges with passive climate ceilings systems?](https://blog.swegon.com/en/addressing-a-design-challenge?hsLang=en)

 Designing indoor climate solutions for modern buildings is a …

Get updates from the blog directly to your inbox.

#### Get to know us

- [Why Swegon?](https://www.swegon.com/why-swegon/)
- [Solutions & services](https://www.swegon.com/solutions-and-services/)
- [Products](https://www.swegon.com/products/)
- [References & Insights](https://www.swegon.com/references-and-insights/)
- [Support & Software](https://www.swegon.com/support/)
- [Sustainability](https://www.swegon.com/sustainability/)

#### More Swegon

- [About us](https://www.swegon.com/about-swegon/)
- [Our Brands](https://www.swegon.com/about-swegon/our-brands/)
- [News](https://blog.swegon.com/en/news?hsLang=en)
- [For suppliers](https://www.swegon.com/for-suppliers/)
- [The Swegon Blog](https://blog.swegon.com/en)
- [Swegon Air Academy](https://www.swegonairacademy.com/en/)

#### Subscribe to The Swegon Blog

[![](https://www.swegon.com/siteassets/logos/logo.svg?v=1620107735)](https://www.swegon.com/)

Swegon Group AB, JA Wettergrens gata 7, SE-421 30 Västra Frölunda, Tel +46 (0)31-89 58 00, Fax +46 (0)31-89 94 69, info@swegon.com

- [Privacy statement](https://www.swegon.com/privacy-policy/)
- [Cookies](https://www.swegon.com/cookies/)
- [Processing personal data](https://www.swegon.com/privacy-policy/processing-personal-data/)

- [![Youtube](https://www.swegon.com/Static/img/youtube.svg)](https://www.youtube.com/user/SwegonAB)
- [![Linkedin](https://www.swegon.com/Static/img/linkedin.svg)](https://www.linkedin.com/company/swegon-ab/)
- [![Facebook](https://www.swegon.com/Static/img/facebook.svg)](https://www.facebook.com/swegongroup)